WW - Worldwide
Select country
 
 
 
 
Order
Printed Media
Instrument Compatibility for qPCR Products
Instrument Compatibility for qPCR Products,
PB_2011_162, 251 KB
Real-time PCR (also called quantitative PCR or qPCR) detects accumulation of amplicon during the reaction, instead of detecting PCR products after the reaction. When detecting reaction products at an exponential phase of their accumulation there is a quantitative relationship between amount of starting template and amount of PCR product at given cycle. Real-time PCR therefore allows quantification of DNA easier and more precise than end-point PCR.

Table. Instrument compatibility.
Product Applied Biosystems Bio-Rad Stratagene Roche Corbett Eppendorf Cepheid
7300, 7900HT, ABI PRISM 7000, ABI PRISM 7700, StepOne Plus, StepOne 7500 iCycler iQ, My iQ, iQ5 Mx4000, Mx3005P, Mx3000P LightCycler 480, LightCycler 2 Rotor-Gene 3000, Rotor-Gene 6000 MasteCycler ep realplex SmartCycler
Maxima® SYBR Green/ROX qPCR Master Mix (2X)
***
*
*
*
*
*
*
*
Maxima® SYBR Green/Fluorescein qPCR Master Mix (2X)
    ***
         
Maxima® SYBR Green qPCR Master Mix (2X), ROX Solution provided
*
***
*
***
***
***
***
***
Maxima® Probe/ROX qPCR Master Mix (2X)
***
*
*
*
*
*
*
*
Maxima® Probe qPCR Master Mix (2X), ROX Solution provided
*
***
***
***
***
***
***
***
*– suitable.
*** – best.
to print - to print
Products » All » PCR, qPCR, RT-PCR & dNTPs » Real-time PCR » Maxima® SYBR Green qPCR Master Mix (2X), ROX Solution provided

Real-time PCR

Maxima® SYBR Green qPCR Master Mix (2X), ROX Solution provided

  • Store at -20°C - Store at -20°C
Catalog# Size, concentration Supplied with: Certificate of Analysis MSDS
Water, nuclease-free ROX Solution (50 µM)
K0251 2 x 1.25 ml (for 200 react. of 25 µl) 2 x 1.25 ml 50.00 µl K0251
K0252 10 x 1.25 ml (for 1000 react. of 25 µl) 10 x 1.25 ml 250.00 µl K0252
K0253 4 x 12.5 ml (for 4000 react. of 25 µl) 2 x 30.00 ml 1.00 ml K0253
Product information
Features

  • Specificity – Maxima® Hot Start Taq DNA Polymerase and the optimized buffer eliminate non-specific amplification and formation of primer dimers.
  • Sensitivity – detects low copy number targets.
  • ROX Solution provided in a separate tube.
  • Wide linear range – accurate quantification across 9 orders of magnitude.
  • Universal – can be used on most real-time PCR instruments.
  • Reproducibility and convenience – ready-to-use 2X master mix.
Applications

  • Real-time PCR and RT-qPCR using SYBR® Green dye on most real-time PCR machines.
Description
Maxima® SYBR Green qPCR Master Mix (2X) is a ready-to-use solution optimized for quantitative real-time PCR and two-step real-time RT-PCR on most real-time PCR machines. The master mix includes Maxima® Hot Start Taq DNA polymerase, SYBR® Green I dye and dNTPs in an optimized PCR buffer. ROX Solution is provided in a separate vial for use with machines that require ROX as a passive reference dye. Maxima® Hot Start Taq DNA polymerase in combination with the optimized buffer ensures PCR specificity and sensitivity. The SYBR® Green I intercalating dye allows for DNA detection and analysis without using sequence-specific probes.

dUTP is included in the mix for optional carryover contamination control using uracil-DNA glycosylase (UDG). The use of Maxima® SYBR Green qPCR Master Mix in real-time PCR ensures reproducible, sensitive and specific quantification of genomic, plasmid, viral and cDNA templates.


Quality Control
The absence of endo-, exodeoxyribonucleases and ribonucleases is confirmed by appropriate quality tests. Functional tests in parallel 25 μl real-time PCR reactions containing 10-fold dilutions of human genomic DNA demonstrate a linear resolution over five orders of magnitude.

Notice
Use of UDG for PCR carryover decontamination is covered by patents in certain countries and may require a license.


Uniform and reproducible results with two different real-time PCR instruments
Figure 1. Uniform and reproducible results with two different real-time PCR instruments.
Amplification of the human cMyc gene was performed on serial dilutions of Jurkat cell total RNA (10 ng to 100 fg). First strand cDNA was synthesized with RevertAid™ Premium Reverse Transcriptase (#EP0731). The resulting cDNA was amplified using the Maxima® SYBR Green qPCR Master Mix (2X) in duplicate reactions. Reactions were performed on ABI 7500 (A) and Corbett RotorGene™ 3000 (B). The amplification plot and the melting curve show high sensitivity and high specificity of the amplification.


Patents, Licenses, Trademarks
Protocols & recommendations
RECOMMENDATIONS FOR USE
Related products
 
 
Contact Us

FERMENTAS INTERNATIONAL INC
tel: 905 333 8355
fax: 905 333 3135
fermentas.info@thermofisher.com

Contact map
Select country