Express DNA Ladders, 100-20000 bp
For fast sizing and quantification of broad range (100-20,000 bp) DNA fragments under a wide variety of electrophoresis conditionsFeatures
- Designed for fast sizing and quantification of DNA fragments.
- Ready-to-use - premixed with a DNA loading dye for direct loading.
- Easy-to-use - fast separation in 5-15 min under various electrophoresis conditions.
- Produce sharp bands.
- Easy-to-remember fragment sizes.
- Ready-to-use versions are stable at room temperature for 6 months.
Description & Other Information
Range Selection Guide
Product List:
- ZipRuler™ Express DNA Ladder Set, ready-to-use (100-20,000 bp)
- MassRuler™ Express DNA Ladder, LR Forward, ready-to-use (100-1000 bp)
- MassRuler™ Express DNA Ladder, LR Reverse, ready-to-use (100-1000 bp)
- MassRuler™ Express DNA Ladder, HR Forward, ready-to-use (1500-10,000 bp)
- MassRuler™ Express DNA Ladder, HR Reverse, ready-to-use (1500-10,000 bp)
- MassRuler™ Express Forward DNA Ladder Mix, ready-to-use (100-10,000 bp)
- MassRuler™ Express Reverse DNA Ladder Mix, ready-to-use (100-10,000 bp)
- GeneRuler™ and O'GeneRuler™ Express DNA Ladders (100-5000 bp)
Product Resources (in pdf):
ZipRuler™ Express DNA Ladder Set, ready-to-use
Designed for fast and accurate broad range (100-20,000 bp) DNA sizing and quantification on agarose gels under various electrophoresis conditions (see Table 1).
ZipRuler™ Express DNA Ladder Set, ready-to-use, is supplied with 6X Orange DNA Loading Dye.More about ZipRuler™ DNA ladders.
ZipRuler™ Express DNA Ladder Set Ladder
formatCatalog
#Certificate
of Analysis
(in pdf)Product
resources
(in pdf)Concentration,
µg/µlAmount,
µgApplications Loading,
µg(µl)/laneRange,
bpFragments Agarose,
%ZipRuler™ Express DNA Ladder 1 Ready-to-use>> #SM1373 0.1 50 100-200 0.25-0.5(2.5-5) 100-10000 9 0.7-2.0 ZipRuler™ Express DNA Ladder 2 200-20000
![]()
Range
ZipRuler™ Express DNA Ladder 1 (9 fragments in bp): 10000, 5000, 3000, 2000, 1200, 850, 500, 300, 100.
ZipRuler™ Express DNA Ladder 2 (9 fragments in bp): 20000, 7000, 4000, 2500, 1500, 1000, 700, 400, 200.Table 1. ZipRuler™ Express DNA Ladder Separation Guide for Various Electrophoresis Conditions.
MassRuler™ Express DNA Ladder, LR Forward, ready-to-use
MassRuler™ Express DNA Ladder, LR Reverse, ready-to-use
Designed for the most accurate quantification of a wide range of DNA fragments. In the forward version, the mass of each DNA fragment is directly proportional to the fragment size, e.g., 10 µl of the ladder contain respectively 100, 70, 50, 30, 20, 10ng of DNA, whereas in the reverse version, the mass is inversely proportional to fragment’s size.
The band pattern is not affected by the composition of electrophoresis buffer, voltage and gel percentage (see Table 2).
MassRuler™ Express DNA Ladders, LR, Forward and Reverse, are supplied with 6X MassRuler™ DNA Loading Dye.More about MassRuler™ DNA ladders.
Ladder
formatCatalog
#Certificate
of Analysis
(in pdf)Product
resources
(in pdf)Concentration,
ng/µlVolume,
µlApplications
0.5 µg/laneLoading,
µl/laneRange,
bpFragments Agarose,
%Ready-to-use>> #SM1263 MSDS (English)
MSDS (English-USA)
MSDS (German)28 2x500 50-200 5-20 100-1000 6 0.7-2.0 #SM1273 MSDS (English)
MSDS (English-USA)
MSDS (German)
Range
6 fragments (in bp): 1000, 700, 500, 300, 200, 100.Table 2. Separation Guide for Various Electrophoresis Conditions.
![]()
MassRuler™ Express DNA Ladder, HR Forward, ready-to-use
MassRuler™ Express DNA Ladder, HR Reverse, ready-to-use
Designed for the most accurate quantification of a wide range of DNA fragments. In the forward version, the mass of each DNA fragment is directly proportional to the fragment size, e.g., 10 µl of the ladder contain respectively 100, 70, 50, 30, 20, 15ng of DNA, whereas in the reverse version, the mass is inversely proportional to fragment’s size.
The band pattern is not affected by the composition of electrophoresis buffer, voltage and gel percentage (see Table 3).
MassRuler™ Express DNA Ladders, HR, Forward and Reverse are supplied with 6X MassRuler™ DNA Loading Dye.More about MassRuler™ DNA ladders.
Ladder
formatCatalog
#Certificate
of Analysis
(in pdf)Product
resources
(in pdf)Concentration,
ng/µlVolume,
µlApplications
0.5 µg/laneLoading,
µl/laneRange,
bpFragments Agarose,
%Ready-to-use>> #SM1243 MSDS (English)
MSDS (English-USA)
MSDS (German)28.5 2x500 50-200 5-20 1500-10,000 6 0.7-1.5 #SM1253 MSDS (English)
MSDS (English-USA)
MSDS (German)
Range
6 fragments (in bp): 10000, 7000, 5000, 3000, 2000, 1500.Table 3. Separation Guide for Various Electrophoresis Conditions
![]()
MassRuler™ Express Forward DNA Ladder Mix, ready-to-use
MassRuler™ Express Reverse DNA Ladder Mix, ready-to-use
Designed for the most accurate quantification of a wide range of DNA fragments. In the forward version, the mass of each DNA fragment is directly proportional to the fragment size, e.g., 10 µl of the ladder contain respectively 100, 70, 50, 30, 20, 15ng of DNA, whereas in the reverse version, the mass is inversely proportional to fragment’s size.
The band pattern is not affected by the composition of electrophoresis buffer, voltage and gel percentage (see Table 4).
MassRuler™ Express DNA Ladder Mixes, Forward and Reverse, are supplied with 6X MassRuler™ DNA Loading Dye.More about MassRuler™ DNA ladders
Ladder
formatCatalog
#Certificate
of Analysis
(in pdf)Product
resources
(in pdf)Concentration,
ng/µlVolume,
µlApplications
0.5 µg/laneLoading,
µl/laneRange,
bpFragments Agarose,
%Ready-to-use>> #SM1283 MSDS (English)
MSDS (English-USA)
MSDS (German)56.5 2x500 50-200 5-20 100-10,000 12 0.7-1.5 #SM1293 MSDS (English)
MSDS (English-USA)
MSDS (German)
Range
12 fragments (in bp): 10000, 7000, 5000, 3000, 2000, 1500, 1000, 700, 500, 300, 200, 100.Table 4. Separation Guide for Various Electrophoresis Conditions.
![]()
GeneRuler™ Express DNA Ladder
GeneRuler™ Express DNA Ladder, ready-to-use
O'GeneRuler™ Express DNA Ladder, ready-to-useDesigned for fast separation (in 5-15 min at 23 V/cm) under a variety of electrophoresis conditions. The band pattern is not affected by the composition of electrophoresis buffer, voltage or gel percentage.
GeneRuler™ Express DNA Ladders are supplied with 6X DNA Loading Dye.
O'GeneRuler™ Express DNA Ladder, ready-to-use, is supplied with 6X Orange DNA Loading Dye.More about GeneRuler™ and O'GeneRuler™ DNA ladders.
Express DNA
laddersLadder
formatCatalog
#Certificate
of Analysis
(in pdf)Product
resources
(in pdf)Concentration,
µg/µlAmount,
µgApplications
0.5 µg/laneLoading amount,
µg(µl)/laneRange,
bpFragments Agarose,
%GeneRuler™ Express Conventional>> SM1551 MSDS (English)
MSDS (English-USA)
MSDS (German)0.5 50 100 0.5 (1) 100-5000 9 1.7-2.5 SM1552 250 (5x50) 500 GeneRuler™ Express Ready-to-use>> SM1553 0.1 50 100 0.5 (5) O'GeneRuler™ Express SM1563 MSDS (English)
MSDS (English-USA)
MSDS (German)
Range
9 fragments (in bp): 5000, 3000, 2000, 1500, 1000, 750, 500, 300, 100.
Fast separation of GeneRuler™ Express DNA Ladder at high voltage (23 V/cm)
Electrophoresis conditions: 0.5 µg/lane, 1% TopVision™ LE GQ Agarose, 1X TAE, 23 V/cm, 5-15 min.
Express DNA Ladders,
flyer in pdf, 124 KBDescription
Express DNA ladders are specifically designed for fast electrophoresis under a wide range of electrophoresis conditions. The band pattern is not affected by the composition of electrophoresis buffer, gel percentage or high voltage. Express DNA ladders allow for rapid and accurate sizing and quantification of broad range (100-20,000 bp) DNA fragments. See Tables 1-4 above for guides for separation of Express DNA ladder's under various electrophoresis conditions.
Express DNA ladders supplement such DNA ladder groups as MassRuler™ DNA ladders, GeneRuler™ and O’GeneRuler™ DNA ladders, and compose ZipRuler™ Express DNA Ladders group.Quality Control
Tested in appropriate gel electrophoresis. The DNA concentration determined spectrophotometrically. The absence of nucleases is confirmed by appropriate tests.Storage
Store at room temperature or at +4°C for 6 months. For longer periods, store at -20°C.
Related Products
| Home | Search | Contacts | Order | Catalog | Support |
Updated balandžio 24, 2008 18:37